Measuring Method: | Manual |
---|---|
Application: | Industry |
Name: | Mineral Insulated Thermocouple Type K |
Size Type: | Type K Miniature Type |
Connector Material: | Plastic |
Pin Material: | +Chromel -Alumel |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
High Temperature GH3030 Mineral Insulated Thermocouple Type K Standard Connector Hollow PIN With Clip
For Mineral insulated (MI) thermocouples, the basic parts are measuring element, insulation, protecting sheath. At most situation, MI thermocouples matched with flexible connector to add bending possibilities and compensation cables to improve the measure accuracy.
Armor Style Thermocouple Structure
Wire Diameter(D) And Tolerance |
Sheath Thickness(S) Mini Value |
Wire Diameter(C) Mini Value |
Insulation Thickness(I) Mini Value |
0.5±0.025 | 0.05 | 0.08 | 0.04 |
1.0±0.025 | 0.10 | 0.15 | 0.08 |
1.5±0.025 | 0.15 | 0.23 | 0.12 |
2.0±0.025 | 0.20 | 0.30 | 0.16 |
3.0±0.030 | 0.30 | 0.45 | 0.24 |
4.5±0.045 | 0.45 | 0.68 | 0.36 |
6.0±0.060 | 0.60 | 0.90 | 0.48 |
8.0±0.080 | 0.80 | 1.20 | 0.64 |
Suppliers with verified business licenses