0.2mm Bright Surface Type N Thermocouple Extension Wire

Product Type: Wire
Material: Nicrsi/Nisimg
Carbon Content: Low Carbon
PCD: No
ET: No
Hole: No
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
N-HP-110
Transport Package
20-25kg/Coil
Specification
0.2mm
Trademark
Ohmalloy
Origin
China
Production Capacity
500000kg Per Month

Product Description

0.2mm Bright surface Type N Thermocouple extension Wire

NiCrSi , NiSiMg Type N Thermocouple Wire Oxidized Style Hot Electrodes

Type: K, E, J, T, N, etc
Style: bright or oxidized
Application: forming two hot electrodes of thermocouple or compensating cable
Place of Origin: Jiangsu, China (Mainland)
Brand Name: Thermocouple wire
Product Size: 0.05mm to 10.0mm
Delivery time: 7-20days which is according to quantity
Eco-friendly: Yes
MOQ: 1kgs
Trade term: FOB, EXW, CIF, CFR
Payment term: T/T, Western Union, L/C
Certificate: ISO,CQC ROHS
Making sample time: all type in stock
Advantage: high quality with high measuring accuracy, fast thermal response, high mechanical strength, long service lifetime, wide temp measuring range of -200-1300centigrade

Classification for thermocouple TYPE N WIRE
Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.
Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.
Thermocouple variety and index for thermocouple TYPE N WIRE
 
Thermocouple Variety and Index
Variety Type Measurement Range(°C)
NiCr-NiSi K -200-1300
NiCr-CuNi E -200-900
Fe-CuNi J -40-750
Cu-CuNi T -200-350
NiCrSi-NiSi N -200-1300
NiCr-AuFe0.07 NiCr-AuFe0.07 -270-0
 
Thermocouple type and grade for thermocouple TYPE K ROD
 
Thermocouple Type Grade Temperature Range(°C) Allowable Deviation
type K and type N I -40-1100 ±1.5°C or±0.4%t
II -40-1300 ±2.5°C or ±0.75%t
III -200-40 ±2.5°C or ±1.5%t
type E I -40-1100 ±1.5°C or ±0.4%t
II -40-1300 ±2.5°C or ±0.75%t
III -200-40 ±2.5°C or±1.5%t
type J I -40-750 ±1.5°C or ±0.4%t
II -40-750 ±2.5°C or ±0.75%t
type T I -40-350 ±0.5°C or± 0.4%t
II -40-350 ±1.0°C or± 0.75%t
III -200-40 ±1.0°C or± 1.5%t
NiCr-AuFe0.07 I -270-0 ±0.5°C
II ±1.0°C
 
 
Specification of alloy wires for thermocouple TYPE N WIRE
 
Anode Cathode Diameter(mm) Maximum Temperature(°C)
name code name code long-time using short-time using
NiCr10(Chromel) KP NiSi3(Alumel) KN Φ0.3 700 800
Φ0.5 800 900
Φ0.8 Φ1.0 900 1000
Φ1.2 Φ1.6 1000 1100
Φ2.0 Φ2.5 1100 1200
NiCr14.2Si NP NiSi4 NN Φ3.2 1200 1300
NiCr10(Chromel) EP CuNi45(Copel) EN Φ0.3 Φ0.5 350 450
Φ0.8 Φ1.0 Φ1.2 450 550
Φ1.6 Φ2.0 550 650
Φ2.5 650 750
Φ3.2 750 900
Fe(Iron) JP CuNi45(Copel) JN Φ0.3 Φ0.5 300 400
Φ0.8 Φ1.0 Φ1.2 400 500
Φ1.6 Φ2.0 500 600
Φ2.5 Φ3.2 600 750
Cu(Copper) TP CuNi45(Copel) TN Φ0.2 Φ0.3 150 200
Φ0.5 Φ0.8 200 250
Φ1.0 Φ1.2 250 300
Φ1.6 Φ2.0 300 350

We are your reliable alloy manufacturer

1.Why choose our high quality thermocouple alloys? 

All our raw material is made from prime material, not recycle material.We have more than 25 years experience in manufacturing thermocouple alloys.

In the market, not all the Thermocouple alloys are with standard chemical composition and stable EMF.Professional and reliable is the soul of our business.

2.DESCRIPTION OF THERMOCOUPLE ALLOYS:

A thermocouple is a temperature measuring device consisting of two conductors of dissimilar metals or alloys that are connected only at the ends.When the ends are at different temperatures a small voltage is produced in the wire that can be related directly to the temperature difference between the ends.If the temperature at one end is known, the temperature at the other end can be determined.

Thermocouple wire or extension grade wire is recommended to be used to connect thermocouples to the sensing or control instrumentation.The conditions of measurement determine the type of thermocouple wire and insulation to be used.Temperature range, environment, insulation requirements, response, and service life should be considered.
Thermocouple temperature range and tolerance

Type
Standard Operating temperature range (°C) Tolerance(°C)
Long term Short term Grade Temperature range Tolerance
Type K GB/T2614 K 1200 1300 I -40~1100 ±1.5°C/±0.4%t
II -40~1300 ±2.5°C/±0.75%t
Type N GB/T17615 N 1200 1300 I -40~1100 ±1.5°C/±0.4%t
II -40~1300 ±2.5°C/±0.75%t
Type E GB/T4993 E 750 900 I -40~800 ±1.5°C/±0.4%t
II -40~900 ±2.5°C/±0.75%t
Type J GB/T4994 J 600 750 I 0~750 ±1.5°C/±0.4%t
II ±2.5°C/±0.75%t
Type T GB/T2903 T 300 350 I -40~350 ±0.5°C/±0.4%t
II ±1°C/±0.75%t
III -200~40 ±1°C/±1.5%t


3.OUR THERMOCOUPLE ALLOYS CHARACTERISTICS:

1)Manufactured according to international quality.System (ISO9001)  IEC584-1 IEC584-2 standard

2)Stable EMF and long-life span

3)Mill test certificate will be provided after production

4)Size range  wire:.0.05-10mm  ribbons:0.05-0.2*2-6mm  strips:0.05-5*5-250mm

5)Good packing methods to keep goods no damage during delivery

6)Customized lable, packing, OEM service

7)24 hours after-sale service

4.MAIN CHARACTERISTICS OF OUR THERMOCOUPLE ALLOYS

TYPE J (Iron vs Constantan) is used in vacuum, oxidizing, inert or reducing atmospheres.Iron element oxidizes rapidly at temperatures exceeding 538'C, and therefore heavier gauge wire is recommended for longer life at these temperatures.

TYPE K (CHROMEL vs ALUMEL ) is used in oxidizing, inert or dry reducing atmospheres.Exposure to vacuum limited to short time periods.Must be protected from sulfurous and marginally oxidizing atmospheres.Reliable and accurate at high temperatures.

TYPE T (Copper vs Constantan) is used or service in oxidizing, inert or reducing atmospheres or in vacuum.It is highly resistant to corrosion from atmospheric moisture and condensation and exhibits high stability at low temperatures.It is the only type with limits of error guaranteed for cryogenic temperatures.

TYPE E (CHROMEL vs Constantan) may be used in oxidizing, inert or dry reducing atmospheres, or for short periods of time under vacuum.Must be protected from sulfurous and marginally oxidizingatmospheres.Produces the highest EMF per degree o any standardized thermocouple.

Type N thermocouple (Ni Cr Si-Ni Si Mg)  is the latest base metal thermocouple, developed to improve the drawbacks that type K thermocouple has.The main chemical composition of positive leg Nicrosil(NP) is Ni:Cr:Si≈84.4:14.2:1.4;Negative leg Nisil (NN) is Ni:Si:Mg≈95.5:4.4:0.1.Type N thermocouple also be used in the similar atmospheres that type K works, and the operating temperature range is -200~1300 °C.