• ANSI Standard Type K Teflon Insulated Thermocouple Extension Cable 0.3mm / 0.5mm / 0.8mm / 1.0mm
  • ANSI Standard Type K Teflon Insulated Thermocouple Extension Cable 0.3mm / 0.5mm / 0.8mm / 1.0mm

ANSI Standard Type K Teflon Insulated Thermocouple Extension Cable 0.3mm / 0.5mm / 0.8mm / 1.0mm

Type: Insulated
Conductor Type: Solid
Application: Thermocouple Wires
Conductor Material: Chromel Alumel
Sheath Material: PTFE / PVC / PFA
Material Shape: Round Wire
Customization:

Contact Supplier

Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
K-HP-1113
Range of Application
Machinery,Thermocouple,Electricity
Certification
ISO9001, ANSI
Brand
Ohmalloy
Transport Package
100m/Spool, 305m/Spool, 1000FT/Spool, 1000m/Spool
Specification
AWG 20 AWG 18 AWG 8
Trademark
OHMALLOY
Origin
China
Production Capacity
500000meters Per Month

Product Description

ANSI standard Type K Teflon Insulated Thermocouple Extension Cable 0.3mm / 0.5mm / 0.8mm / 1.0mm

 

Specifications

1.Style:Extension Wire
2.Thermocouple copper wire
Thermocouple copper wire Classification
1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.
2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.

Thermocouple variety and index


Thermocouple Variety and Index

Variety

Type

Measurement Range(°C)

NiCr-NiSi

K

-200-1300

NiCr-CuNi

E

-200-900

Fe-CuNi

J

-40-750

Cu-CuNi

T

-200-350

NiCrSi-NiSi

N

-200-1300

NiCr-AuFe0.07

NiCr-AuFe0.07

-270-0

 

3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire

Dimensions / Tolerance mm ) : 4.0+-0.25


Color code & initial calibration tolerances for thermocouple wire:

Thermocouple Type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
Iron(+) vs.
Constantan(-)
J White/Red Brown 0°C to +285°C
285°C to +750°C
±2.2°C
± .75%
±1.1°C
± .4%
CHROMEL(+) vs.
ALUMEL(-)
K Yellow/Red Brown -200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C
± 2%
±2.2°C
±2.2°C
± .75%
±1.1°C
± .4%
Copper(+) vs.
Constantan(-)
T Blue/Red Brown -200°C to -65°C
-65°C to +130°C
130°C to +350°C
± 1.5%
±1°C
± .75%
± .8%
± .5°C
± .4%
CHROMEL(+) vs.
Constantan(-)
E Purple/Red Brown -200°C to -170°C
-170°C to +250°C
250°C to +340°C
340°C+900°C
± 1%
±1.7°C
±1.7°C
± .5%
±1°C
±1°C
± .4%
± .4%


Color Code & Initial Calibration Tolerance for Extension Wire:

Extension type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
Iron (+) vs. Constantan(-) JX White/Red Black 0°C to +200°C ±2.2°C ±1.1°C
CHROMEL (+) vs. ALUMEL (-) KX Yellow/Red Yellow 0°C to +200°C ±2.2°C ±1.1°C
Copper(+) vs. Constantan(-) TX Blue/Red Blue -60°C to +100°C ±1.1°C ± .5°C
CHROMEL(+) vs. Constantan(-) EX Purple/Red Purple 0°C to +200°C ±1.7°C ±1.1°C


PVC-PVC Physical Properties:

Characteristics Insulation Jacket
Abrasion Resistance Good Good
Cut Through Resistance Good Good
Moisture Resistance Excellent Excellent
Solder Iron Resistance Poor Poor
Service Temperature

105ºC continuous

150ºC single

105ºC continuous

150ºC single

Flame Test Self-extinguishing Self-extinguishing

ANSI Standard Type K Teflon Insulated Thermocouple Extension Cable 0.3mm / 0.5mm / 0.8mm / 1.0mm

 

Send your message to this supplier

*From:
*To:
avatar Mr. Qiu
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now