Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Stranded |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SWG 18 ANSI Standard Type K Thermocouple Compensation Cable FEP Insulation
Type K Thermocouple Bare Wire
Type K( CHROMEL vs ALUMEL) is used in oxidizing, insert or dry reducing atmospheres.Exposure to Vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres.Reliable and accurate at high temperatures.
1. Chemical Composition
Material | Chemical composition(%) | ||||
Ni | Cr | Si | Mn | Al | |
KP(Chromel) | 90 | 10 | |||
KN(Alumel) | 95 | 1-2 | 0.5-1.5 | 1-1.5 |
2.Physical properties and Mechnical properties
Material | Density(g/cm3) | Melting point(°C) | Tensile Strength(Mpa) | Volume resistivity(μΩ.cm) | Elongation rate(%) |
KP(Chromel) | 8.5 | 1427 | >490 | 70.6(20°C) | >10 |
KN(Alumel) | 8.6 | 1399 | >390 | 29.4(20°C) | >15 |
3.EMF Value range at different temperature
Material | EMF value Vs Pt(μV) | |||||
100°C | 200°C | 300°C | 400°C | 500°C | 600°C | |
KP(Chromel) | 2816-2896 | 5938-6018 | 9298-9378 | 12729-12821 | 16156-16266 | 19532-19676 |
KN(Alumel) | 1218-1262 | 2140-2180 | 2849-2893 | 3600-3644 | 4403-4463 | 5271-5331 |
EMF value Vs Pt (μV) | ||||
700°C | 800°C | 900°C | 1000°C | 1100°C |
22845-22999 | 26064-26246 | 29223-29411 | 32313-32525 | 35336-35548 |
6167-6247 | 7080-7160 | 7959-8059 | 8807-8907 | 9617-9737 |
Payment&Shippment: