Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I

Product Details
Customization: Available
Type: Insulated
Conductor Type: Stranded
Still deciding? Get samples of US$ 0/Meter
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (6)
  • Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I
  • Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I
  • Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I
  • Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I
  • Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I
Find Similar Products

Basic Info.

Model NO.
SP-KX-FB-0.81
Conductor Material
Chromel Alumel
Sheath Material
Fiberglass
Insulation Material
Fiberglass
Material Shape
Round Wire
Range of Application
Temperture Measurement
Certification
CCC, RoHS
Brand
Ohmalloy/OEM
Product Name
Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable
Jacket Material
Fiberglass
Cunstomized Service
Color, Insulation,Package
MOQ for Customize
100 Meter
Application Way
Thermocouple Cable
Transport Package
Coil+ Waterproof Paper+ Wooden Case
Specification
2*0.81mm
Trademark
Ohmalloy/OEM
Origin
Jiangsu
HS Code
9025900090
Production Capacity
10000 Meter/Day

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 15.00cm
Package Gross Weight
2.000kg

Product Description

KX-FB-0.81 Fiberglass Insulated Thermocouple Cable Type K 100M/Coil Extension Class I

Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I

For the extension/compensation cable, the basic structure is conductor and insulation.

To increase its temperature bearing ability and to install easily, jacket is applicable.

In the working environment, there are too much factors will interference the EMF signal, therefore shield layer is practical way to prevent the cable from interference caused by complex environment.
 

Product name

Issuing Date

Drawing no.

Version

Type K cable

 

 

A/1

Item

KX-VS-0.8

Size

0.8mm

Max temp

980ºC

Voltage

 

Drawing or picture

Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I 

Spec

Unit

Standard requirement

Conductor

Conductor structure

N/mm

Solid type

Conductor material

Positive leg (+)

Chromel

Negative leg(-)

Alumel

OD of conductor

mm

0.8mm

Pairs

 

 

 

WRAPING

 

--

-----

Insulation

Material

--

Vitreous Silica

Insulation thickness

mm

0.45

Min thickness

mm

0.4

OD of each core

mm

1.7

Color

Positive leg(+)

Yellow

Negative leg(-)

Red

Shielding

Material

--

/

Covering density

%

/

Jacket

Material

--

 

Thickness

--

 

OD of whole cable

--

 

Color of jacket

--

/

Electrical

Voltage test

V/min

/

Drain wire

Material

 

/

Size

 

/

 

1. The Compensation Wire Name and Code

Compensation Alloy Wire Name Positive Negative
Name Code Name Code
Copper-Copper Nickel 0.6 Copper SPC Copper Nickel 0.6 SNC
Copper-Copper Nickel 0.6 Copper RPC Copper Nickel 0.6 RNC
Iron-Copper Nickel 22 Iron KPCA Copper Nickel 22 KNCA
Copper-Copper Nickel 40 Copper KPCB Copper Nickel 40 KNCB
Chromel-NiSi3 Ni90Cr10 KPX Ni97Si3 KNX
Iron-Copper Nickel 18 Iron NPC Copper Nickel 18 NNC
NiCr14Si-NiSi4Mg NiCr14Si NPX NiSi4Mg NNX
NiCr10-Copper Nickel 45 NiCr10 EPX Copper Nickel 45 ENX
Iron-Copper Nickel 45 Iron JPX Copper Nickel 45 JNX
Copper-Copper Nickel 45 Copper TPX Copper Nickel 45 TNX


2. How To Choose Thermocouple

Type Insulation material CODE Inner Shielding CODE JACKET CODE Out shielding CODE Pairs solid Earth wire Stranded
K FEP FP     FEP FP     0 0.2mm E cross section+R
T PFA FA Al foil AL PFA FA copper wire CU 2 0.3mm    
E PVC 70ºC LP copper wire CU PVC 70ºC LP Tinned copper TC 3 0.5mm    
J PVC 105ºC HP Tinned copper TC PVC 105ºC HP Nickel plated copper NC 4 0.75mm    
N Fiberglass 400ºC BL Nickel plated copper NC Fiberglass 400ºC BL Silver plated copper AC 5 1.0mm    
SC Fiberglass600ºC BM Silver plated copper AC Fiberglass600ºC BM SS 304 wire SS 6 1.5mm    
  Fiberglass700ºC BH     Fiberglass700ºC BH            
  MICA FIBER 650ºC MA                    
KCA Vitreous Silica 800ºC VS SS 304 wire SS Vitreous Silica 800ºC VS     7 2.5mm    
KCB Silica fiber1000ºC SV Inconel 600 wire 600 Silica fiber1000ºC SV     8      
RTD Ceramic fiber1200ºC CF Inconel 625 wire 625 Ceramic fiber1200ºC CF     9      
  PTFE PT     PTFE PT            
  ETFE ET     ETFE ET            
  KAPTON KP     KAPTON KP            
  Silcone rubber SR     Silcone rubber SR            
  Rubber RU     Rubber RU            
  PE PE     PE PE            

The Position Wire VS Pt Nominal Thermoelectromotive Force Vaule Reference

Extension Cable Code Alloy Wire Code Application Classifica-tion

Measurement Terminal Temperature

(ºC)

Nominal Thermoelectrom-otive force(μV) Precision Grade Thermoelectrom-otive force(μV) Normal Grade Thermoelectrom-otive force(μV)

Tolera-

nce

Value Range

Toler-

ance

Value Range
SC or RC or KCB SPC or RPC or KPCB G 100 773 ±10 763~783 ±12 761~785
H 100 773 - - ±12 761~785
200 1837 - - 1825~1849
TX TPX G -25 -135 ±10 -125~-145 ±12 -123~-147
100 773 763~783 761~-785
H -25 -135 ±10 -125~-145 ±12 -123~-147
100 773 763~783 761~785
200 1837 1827~1847 1825~1849
KX KPX G -25 -626 ±29 -597~-655 ±57 -569~-683
100 2856 2827~2885 2799~2913
H -25 -626 ±29 -597~-655 ±57 -569~-683
100 2856 2827~2885 2799~2913
200 5978 5949~6007 5892~6035
EX EPX G -25 -626 ±34 -592~-660 ±55 -571~-681
100 2814 2780~2848 2759~2869
H -25 -626 ±34 -592~-660 ±55 -571~-681
100 2814 2780~2848 2759~2869
200 5970 5936~6004 5915~6025
NX NPX G -25 -368 ±29 -339~-397 ±56 -312~-424
100 1784 1755~1813 1728~1840
H -25 -368 ±29 -339~-397 ±56 -312~-424
100 1784 1755~1813 1728~1840
200 3943 3914~3972 3887~3999

 

2. Size Range Reference
Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I

 

3. Production Progress

Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I

4. Package Reference

Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I
 

5. Our Service

Kx-Fb-0.81 Fiberglass Insulated Thermocouple Cable Type K 100m/Coil Extension Class I
 

6. Questions and Answers

 

Q1:How can I contact with your company?

A1:We have multiple communication channels    

 

Q2:Do you provide free samples?

A2:Yes,we can provide free samples for your testing,but buyer should bear the shipping costs.

 

Q3:What is your payment terms?

A3:30% in advance,balance after receiving the copy of B/L. T/T,L/C,Western Union,Paypal is OK.

 

Q4:What is your lead time?

A4:On normal condition,the lead time is 7 days after the payment. Special order or quantity is subject to the negotiation.

 

Q5:What is your working time?

A5: Monday to Firday: 9:00-12:00,13:30-17:30, rest in weekend.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier