• Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass
  • Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass
  • Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass
  • Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass
  • Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass

Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass

Type: Insulated
Conductor Type: Solid
Application: Temperture Measurement
Conductor Material: + Chromel -Alumel
Sheath Material: FEP
Insulation Material: Teflon
Samples:
US$ 0/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
SP-KX-FB-FB-SS304-1.5R
Material Shape
Flat Wire
Range of Application
Temperture Measurement
Certification
CCC, RoHS
Brand
Ohmalloy/OEM
Product Name
Type K Thermocouple Extension Cable ANSI IEC JIS S
Jacket Material
Fiberglass(400/600/800/1000/1200 Degree Celsius)
Sheath Type
SS304/Copper/Tinnned Copper
Color Code
ANSI/IEC/JIS/DIN/BS
Cunstomized Service
Color, Insulation,Package
MOQ for Customize
500 Meter
Transport Package
Coil+ Waterproof Paper+ Wooden Case
Specification
1.5R*2(19*0.30mm)
Trademark
Ohmalloy/OEM
Origin
Jiangsu
HS Code
9025900090
Production Capacity
10000 Meter/Day

Product Description

Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass

 

 
Cable Specification
Item Name Type KX Extension Cable Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass
Conductor Material +Chromel -Alumel
Conductor Dia 19/0.3mm(1.5mm2, ±0.01mm)
Insulation and Thickness Fiberglass(long term: 400ºC short term:500ºC) 0.2mm
Insulation Diameter 2.0mm(±0.2mm)
Jacket Material Fiberglass(long term: 400ºC short term:500ºC) 0.2mm
Outer Sheath SS304 Braiding
Outer Insulated Diameter 5.2*4.1mm(±0.2mm)
Weight 49KG/KM
Color Code IEC-584-3 (+Green -White Overall:Green Tracer)  


In actual temperature measurement, usually there are long measuring distance with the measuring device, a thermocouple compensation wire is generated to compensate the temperature difference caused by the temperature change between the measuring device and the thermocouple connecting piece.

 

The compensation cable has the following advantages: improving thermocouple temperature measurement line physical properties and mechanical properties; improving the measurement line flexibility and making the connection convenient by using multi-strand core or small-diameter compensation wire; easy to shield external interference; reducing measuring lines cost.

 

Thermocouple Cable Grade

A:Extension Grade Cable

Whose wire composition is totally as the same as the thermocouple wire, remarked by the letter"X"after the thermocouple symbol number, such as"KX""JX""TX"

B:Compensation Grade Cable

Whose wire composition is different from the thermocouple wire, but its wire electromotive force (EMF) value is the same as thermocouple wire only at 0-100ºC or 0-200ºC. It remarked by the letter"C"after the thermocouple symbol number, such as"KC""JC""TC"

  1. For cost consideration, when the tested temperature under 200ºC, compensation grade cable is preferred. But compensation grade cable will occur enormous tested temperature value deviation if the tested temperature above 200ºC. The higher the tested temperature, the greater deviation be.
  2. For compensation grade cable, the max testing temperature is less than 200ºC, the bigger the cable, the smaller the signal loss.
  3. Extension cable and compensation cable comparison:

 

    Performance

Extension Grade Compensation Grade

Material

Same as thermocouple Different from thermocouple
EMF Value Feature Same as the thermocouple's at certain temperature range Same as the thermocouple's
Deviation Curve Nonlinear, varies with temperature

  Linear

Working Temperature Range Limited(usual at 100ºC) Unlimited(depend on insulation material temperature bearing)
Line Resistance Low resistance High resistance
Compensation Contact Interference Different contactor material may cause interference

None

Accuracy

Low

High

Price

Low

High(about 1-2 times higher)

Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass
 

2. Size Range Reference
Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass

 

3. Production Progress

Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass

4. Package Reference

Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass
 

5. Our Service

Type K Thermocouple Extension Cable ANSI IEC JIS Standard SS304 Sheath Fiberglass
 

6. Questions and Answers

 

Q1:How can I contact with your company?

A1:We have multiple communication channels    

 

Q2:Do you provide free samples?

A2:Yes,we can provide free samples for your testing,but buyer should bear the shipping costs.

 

Q3:What is your payment terms?

A3:30% in advance,balance after receiving the copy of B/L. T/T,L/C,Western Union,Paypal is OK.

 

Q4:What is your lead time?

A4:On normal condition,the lead time is 7 days after the payment. Special order or quantity is subject to the negotiation.

 

Q5:What is your working time?

A5: Monday to Firday: 9:00-12:00,13:30-17:30, rest in weekend.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Import & Export Mode
Have Own Export License
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, DDP, DAP, CIP, CPT, FCA, EXW, Others