• Mineral Insulated Heating Wire 0cr20ni80 Mi High Temperature Wire
  • Mineral Insulated Heating Wire 0cr20ni80 Mi High Temperature Wire
  • Mineral Insulated Heating Wire 0cr20ni80 Mi High Temperature Wire
  • Mineral Insulated Heating Wire 0cr20ni80 Mi High Temperature Wire

Mineral Insulated Heating Wire 0cr20ni80 Mi High Temperature Wire

Type: Insulated
Conductor Type: Solid
Application: Temperture Measurement
Conductor Material: 0cr20ni80
Sheath Material: Stainless Steel/High Temperature Alloy/Inconel
Insulation Material: MGO/Al2O3
Samples:
US$ 100/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
SP-MI-2080
Material Shape
Round Wire
Range of Application
Insulated Resistance Wire
Certification
RoHS
Brand
Ohmalloy/OEM
Name
Mineral Insulated Heating Wire 0cr20ni80 Mi High T
Mi Length
as Customer Requirement
Tail Handling
Sealed or Open(as Customer Requirement)
Transport Package
Plywood Case
Specification
As customer requirement
Trademark
OHMALLOY/OEM
Origin
China
HS Code
85444929
Production Capacity
100000 Meters / Month

Product Description

Mineral Insulated Heating Wire 0Cr20Ni80 MI High Temperature Wire

For Mineral insulated (MI) thermocouples, the basic parts are measuring element, insulation, protecting sheath. At most situation, MI thermocouples matched with flexible connector to add bending possibilities and compensation cables to improve the measure accuracy.

It is known as inorganic substance insulation thermocouple cable internationally. It is the mould-pressed solid integrity of combined stainless steel protective pile

(1) magnesium oxide insulation powder.

(2) and thermocouple thread materials .

(3) Its merits include press endurance, vibration resistance, bending capability, mini size, quick respond, etc. It acts as the key material of sheath
Mineral Insulated Heating Wire 0cr20ni80 Mi High Temperature Wire

 

Electric property:

Resistance value allowance:±10%

Dielectric property:heating cable pressure resist:1200V AC/1min

Insulation resistance:end product test:100MΩ/500VDC

Sheath continuity:all the heating cable submerged in the water 12 hours then test the insulation resistance,

the value should be 50M/500VDC at least.


To produce assemblies, the cable is cut to the desired length, pigtails brazed on and terminated with union type glands with male NPT threads.

 

Mineral Insulated Parts Standards
Mineral Insulated Heating Wire 0cr20ni80 Mi High Temperature Wire

 

Unit: MM

Wire Diameter(D)

And Tolerance

Sheath Thickness(S)

Mini Value

Wire Diameter(C)

Mini Value

Insulation Thickness(I)

Mini Value

0.5±0.025 0.05 0.08 0.04
1.0±0.025 0.10 0.15 0.08
1.5±0.025 0.15 0.23 0.12
2.0±0.025 0.20 0.30 0.16
3.0±0.030 0.30 0.45 0.24
4.5±0.045 0.45 0.68 0.36
6.0±0.060 0.60 0.90 0.48
8.0±0.080 0.80 1.20 0.64

Send your message to this supplier

*From:
*To:
avatar Mr. Qiu
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now