Customization: | Available |
---|---|
Name: | Ptrh10 Ptrh13 Ptrh30/6 Platinum Rhodium Wire |
Shape Supply: | Wire |
Still deciding? Get samples of US$ 50/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Thermocouple Type
|
Alloy Code
|
Chemical Composition (%)
|
Recommend Long Working Temperature
|
|
Pt (platinum)
|
Rh (Rhodium )
|
|||
Type S
|
SP(Pt90Rh)
|
90
|
10
|
0-1300ºC
|
SN(Pt)
|
100
|
|
||
Type B
|
BP(Pt70Rh)
|
70
|
30
|
0-1600ºC
|
BN(Pt94Rh)
|
94
|
6
|
||
Type R
|
RP(Pt87Rh)
|
87
|
13
|
0-1300ºC
|
RN(Pt)
|
100
|
|
Thermocouple Type
|
Long Working TemperatureºC
|
Max Short Working TemperatureºC
|
Type S
|
1300
|
1600
|
Type R
|
1300
|
1600
|
Type B
|
1600
|
1700
|
Physical parameter
|
|||||
Item
|
Pt90Rh
|
Pt
|
Pt87Rh
|
Pt70Rh
|
Pt94Rh
|
Melting PointºC
|
1847
|
1769
|
1860
|
1927
|
1826
|
Density(g/cm3)
|
20.00
|
21.46
|
19.61
|
17.60
|
20.60
|
Weight per meter/g (Φ0.5mm)
|
3.93
|
4.21
|
3.82
|
3.45
|
4.04
|
Resistivity at 20ºC/µΩcm
|
18.9
|
10.4
|
19.6
|
19.0
|
17.5
|
Average temperature coefficient of resistance(0-1200ºC)/(10-4/ºC)
|
14
|
31
|
13.3
|
13.3
|
20.6
|
Tensile Strength/MPa
|
314
|
137
|
344
|
483
|
276
|
Elongation Rate(L0=100mm)/%
|
35
|
40
|
35
|
30
|
35
|
Temperature Tolerance
|
|||
Thermocouple Type
|
Accuracy Grade
|
Testing Temperature Range/ºC |
Allowable Deviation/ºC
|
Type S(Type R) |
I
|
0-1100
|
+/-1
|
1100-1600
|
+/-1+(t-1100)*0.3%
|
||
II
|
0-600
|
+/-1.5
|
|
600-1600
|
+/-0.25%*t
|
||
Type B
|
II
|
600-1700
|
+/-0.25%*t
|
III
|
600-800
|
+/-4
|
|
800-1700
|
+/-0. 5%*t
|
||
"T"is the measuring terminal temperature
|