Electric Wire PVC Thermocouple Cable

Product Details
Customization: Available
Product Type: Wire
Material: Nicr/Nial
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (6)
Find Similar Products

Basic Info.

Model NO.
K-HP-122
PCD
No
ET
No
Hole
No
Color
Customizable
Transport Package
100m/Roll, 500m/Spool, 1000m/Drum
Specification
Customizable
Trademark
OHMALLOY
Origin
China
Production Capacity
500000 Meter/Meters Per Month

Product Description

Electric wire PVC thermocouple cable

Type K (CHROMEL vs ALUMEL ) is used in oxidizing, inert or dry reducing atmospheres. Exposure to vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperatures.
1. Chemical Composition
Material Chemical composition (%)
Ni Cr Si Mn Al
KP(Chromel) 90 10      
KN(Alumel) 95   1-2 0.5-1.5 1-1.5
2. Physical properties and Mechnical properties
Material Density(g/cm3) Melting point(ºC) Tensile Strength(Mpa) Volume resistivity(μΩ.cm) Elongation rate (%)
KP(Chromel) 8.5 1427 >490 70.6(20ºC) >10
KN(Alumel) 8.6 1399 >390 29.4(20ºC) >15
3. EMF Value range at different temperature
Material EMF value Vs Pt(μV)
100ºC 200ºC 300ºC 400ºC 500ºC 600ºC
KP(Chromel) 2816~2896 5938~6018 9298~9378 12729~12821 16156~16266 19532~19676
KN(Alumel) 1218~1262 2140~2180 2849~2893 3600~3644 4403~4463 5271~5331
 
EMF value Vs Pt(μV)
700ºC 800ºC 900ºC 1000ºC 1100ºC
22845~22999 26064~26246 29223~29411 32313~32525 35336~35548
6167~6247 7080~7160 7959~8059 8807~8907 9617~9737

Type K Extension Cable Chromel / Alumel Material FEP insulation
Specifications
1.Style:Extension Wire
2.Thermocouple copper wire
Thermocouple copper wire Classification
1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.
2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.
Thermocouple variety and index

Thermocouple Variety and Index

Variety

Type

Measurement Range(°C)

NiCr-NiSi

K

-200-1300

NiCr-CuNi

E

-200-900

Fe-CuNi

J

-40-750

Cu-CuNi

T

-200-350

NiCrSi-NiSi

N

-200-1300
NiCr-AuFe0.07 NiCr-AuFe0.07
-270-0
 
3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire
 Dimensions / Tolerance mm ) : 4.0+-0.25
Color code & initial calibration tolerances for thermocouple wire:
Thermocouple Type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
CHROMEL(+) vs.
ALUMEL(-)
K Yellow/Red Brown -200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C
± 2%
±2.2°C
±2.2°C
± .75%
±1.1°C
± .4%

Color Code & Initial Calibration Tolerance for Extension Wire:
Extension type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
Iron (+) vs. Constantan(-) JX White/Red Black 0°C to +200°C ±2.2°C ±1.1°C
CHROMEL (+) vs. ALUMEL (-) KX Yellow/Red Yellow 0°C to +200°C ±2.2°C ±1.1°C
Copper(+) vs. Constantan(-) TX Blue/Red Blue -60°C to +100°C ±1.1°C ± .5°C
CHROMEL(+) vs. Constantan(-) EX Purple/Red Purple 0°C to +200°C ±1.7°C ±1.1°C

PVC-PVC Physical Properties:
Characteristics Insulation Jacket
Abrasion Resistance Good Good
Cut Through Resistance Good Good
Moisture Resistance Excellent Excellent
Solder Iron Resistance Poor Poor
Service Temperature 105ºC continuous
150ºC single
105ºC continuous
150ºC single
Flame Test Self-extinguishing Self-extinguishing
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier